What winter here does to a heat pump
Your furnace or heat pump runs about ten months a year here, September through June, so this is mostly a heating decision. The overnight low averages 26°F across December, January and February, and that number is the one that matters most. A standard heat pump starts falling short of its rated heat output below 40°F, and below about 35°F it often needs backup heat to keep up. The average winter night here is below both marks, and so is every one of the roughly 100 nights a year that hit freezing or colder.
That doesn't mean the heat pump quits. About 100 of the 305 nights in the heating season drop to freezing or below, which still leaves most nights where a standard heat pump runs closer to its rated output. True cold, 0°F or below, shows up only about one night a year here. A heat pump certified as ENERGY STAR Cold Climate has to make at least 1.75 units of heat per unit of electricity at 5°F and hold at least 70 percent of its 47°F capacity at that same temperature, verified by outside testing. Field tests of these units found backup heat covered only a small share of total output between 0°F and 35°F, and running on backup alone was rare even at 0°F. A gas furnace built to the federal minimum doesn't have any of this to work around. It burns gas and puts out its full rated heat whether it's 30°F outside or far below.