What winter here does to a heat pump
Your furnace or heat pump runs eight months a year here, October through May, and the overnight low averages 25°F across December, January and February. That's the number that decides this. A standard heat pump starts losing ground to its own rating below 40°F, and below about 35°F it typically needs backup heat to keep up. Both marks sit above your average winter night, not below it.
About 120 nights a year here drop to freezing or below, roughly half the nights across the whole heating season. Every one of those nights is already under both the 40°F and 35°F marks. This isn't a once-in-a-while dip into territory a heat pump struggles with. It's half the winter.
The cold snaps are rare. Only about one night a year reaches 0°F here, so the deep cold isn't the issue. A cold climate heat pump, the kind certified to hold at least 70 percent of its capacity and still produce 1.75 units of heat per unit of electricity at 5°F, is built for exactly those rare nights and tested to prove it. Field testing on prototype cold-climate units backs this up: backup heat covered only a small share of the output between 0°F and 35°F, and running on backup alone was rare even above 0°F. A furnace never has this problem, because it makes its full rated heat regardless of what it is outside.