What the cold does to a heat pump here
Your winter low here averages 18°F, and that is the number this choice turns on. A standard heat pump's output falls short of its rating once it is below 40°F outside, and it often needs backup heat below about 35°F. Eighteen degrees is under both marks. So is every one of the roughly 160 nights a year here that hit freezing or below, more than half the nine months your heat runs.
That does not mean a heat pump will not heat your house. It means that on most winter nights here, it is running below its rated output and leaning on backup heat to cover the rest. A gas furnace does not have that problem. It burns gas and makes its full heat whether it is 30°F outside or 0°F.
The nights that reach 0°F, about 5 a year, are rare, and backup heat alone was rarely needed even at that mark in field tests of cold-climate units. The real question is the other 160 nights, the ones at or below freezing, because that is where a standard heat pump spends most of its winter working harder for less.
There is a real fix for this. A heat pump built to the ENERGY STAR Cold Climate spec is tested to hold at least 70 percent of its rated heat at 5°F and still make 1.75 units of heat for every unit of electricity it uses at that temperature. That changes the argument. A standard heat pump at the federal minimum does not come with that guarantee.