Why winter decides this
Your heat runs about ten months a year here, September through June. Cooling only runs about two, July and August. Whatever you buy is going to be judged mostly on how it handles January, not July.
The overnight low averages 11°F across December, January and February. A standard heat pump falls short of its rated heat output once it's below 40°F outside, and often needs backup heat once it's below about 35°F. Eleven degrees is past both marks, and that's just the average, not the coldest it gets.
About 170 nights a year here drop to freezing or below, more than half the nights across the time your heat runs. Every one of those nights is cold enough that a standard heat pump is working below its rated capacity. About 11 nights a year reach 0°F or below. That's a small share of the cold nights here, but the ordinary freezing night, the kind this county gets more than 170 of, is already past where a standard heat pump performs at its rating.
A heat pump built to the ENERGY STAR Cold Climate spec is held to a different mark: it has to produce at least 1.75 units of heat for every unit of electricity at 5°F, and keep at least 70 percent of its 47°F capacity at that same temperature, verified by outside testing. In a two-winter field test of prototype cold-climate units in occupied homes, backup heat covered only a small share of the load between 0°F and 35°F, and the units running on backup alone was rare even above 0°F. A furnace never needs that kind of rating because it makes the same heat no matter how cold it gets outside. If a heat pump is on the table here, which model it is matters more than it would somewhere with a milder winter.