Age changes the math
An older compressor has already logged a lot of cycles. One more part failing on a unit that old is a sign the rest isn't far behind it. Spending on a repair there is a bet against the next failure coming soon after.
Takes about a minute. No obligation.
Winter nights here average 11 degrees, and a heat pump is built to work in that kind of cold. When one stops keeping up, the cause is usually something a tech sees all the time. A dirty outdoor coil. A low refrigerant charge. A defrost control that quit switching over. Nothing about Rigby winters is hard enough to cause that on its own. It is wear and parts doing what parts eventually do, and a tech can usually trace the problem to one part rather than the whole system.

NOAA nClimDiv, 1991–2020 normals
Heat here runs ten months a year, September through June.
A heat pump that struggled last season will struggle again come September, right when the load comes back on it.




The reversing valve is the part most specific to a heat pump, and it is often the one that fails first. It is what lets the system switch between heating and cooling, and when it sticks, the unit can get stuck blowing cold air or short cycling between modes. The defrost sensor is another common point of failure. It tells the system when frost has built up on the outdoor coil and needs to melt off, and if it fails, ice keeps building until the coil is blocked and airflow drops off. Contactors and capacitors wear out from the outdoor unit simply cycling on and off thousands of times, and when they go, the compressor or the fan may not start at all. A low refrigerant charge almost always means a leak somewhere in the lines or coil, not normal use, since a sealed system does not lose refrigerant on its own.
A system that came with a newer house still has most of its working life ahead of it. That's a reason to get the repair looked at rather than put off or replaced outright.
Find a contractorA compressor that's struggling still tries to do the job it's told. If the charge is low or the coil is dirty, it runs longer to make up for it, and that extra runtime is hard on the windings and the oil that lubricates them. A reversing valve that's starting to stick gets worse with every cycle, since each switch between heating and cooling is what wears the seal inside it. Ice on the outdoor coil behaves the same way. A little frost melts off fine, but once airflow drops, the coil gets colder, which grows more frost faster than the defrost cycle can clear it. Left alone, that kind of problem doesn't plateau. It compounds.
An older compressor has already logged a lot of cycles. One more part failing on a unit that old is a sign the rest isn't far behind it. Spending on a repair there is a bet against the next failure coming soon after.
A stuck reversing valve or a bad capacitor is a single part doing its job wrong. The compressor, the coil and the blower motor keep their value even when one component quits. Replacing the failed part is usually cheaper than replacing everything around it that still works fine.
Before anyone comes out, there are a few things worth checking. Look at the outdoor unit. If the coil is caked in ice or buried in leaves and debris, airflow is choked off and the system can't move heat the way it needs to. Check the thermostat batteries and make sure it's set to heat, not auxiliary or off. Walk around the house and check that supply vents are open and not blocked by furniture or rugs, since a heat pump already moves cooler air than a furnace and needs that airflow to do its job. Check the breaker panel too. A tripped breaker will shut the whole system down and looks, from inside the house, like the heat pump just quit. None of this fixes a bad reversing valve or a refrigerant leak, but it rules out the simple stuff first.
A diagnostic visit starts outside, at the unit itself. A tech checks the coil, watches the fan, and reads the refrigerant pressures, since that's where a heat pump shows its problems first. Gauges on the lines show whether the charge is low and roughly where a leak might be hiding. Inside, the tech checks the filter and the temperature split between the air going in and the air coming out. A weak split points straight at airflow or refrigerant trouble. Capacitors and contactors get tested under load, because a part can look fine sitting still and still fail the moment it's asked to do its job. Most of this gets done with the system running, not shut off, since a lot of these problems only show up while the compressor and reversing valve are actually working.