Can a heat pump keep up with winter here
Your winter decides this, not the sticker on the machine. The overnight low here averages 16°F across December, January and February, and that is not a cold snap, that is the season. A standard heat pump starts falling short of its rated heat output below 40°F and often needs backup heat below about 35°F. Here, every one of the roughly 175 nights a year at or below freezing falls under both marks, over half the nights in the ten months your heat runs.
That does not mean a heat pump quits on you. It means a plain, federal-minimum heat pump is leaning on backup heat for a lot of the winter, not just the coldest nights. The ENERGY STAR Cold Climate models are built for exactly this case. To carry that label, a heat pump has to keep making at least 1.75 units of heat for every unit of electricity at 5°F, and hold onto most of its 47°F capacity at that same temperature, checked by outside testing. Field tests on prototype cold-climate units in occupied homes back this up. Over two winters, backup heat covered only a small share of the heat needed between 0°F and 35°F, and the system running on backup alone was rare even above 0°F.
So the honest answer depends on which heat pump you mean. A federal-minimum unit will lean hard on backup heat through a Franklin County winter. A cold-climate unit is built to carry most of that load itself. The roughly 8 nights a year that reach 0°F or below are a small slice of the season, but they are the nights that decide how much backup heat the system needs on hand. Everything else, the long stretch of 20s and 30s, is the range a cold-climate heat pump is built to handle.