What winter here does to a heat pump
Winter is the long season here, eight months of it, October through May, against three months of cooling. Whatever you install is mostly a heating decision, not a cooling one.
A standard heat pump starts losing ground before it gets cold by most people's definition. Below 40°F its heat output falls short of its rated capacity, and below about 35°F it often needs backup heat to keep up. The average overnight low here in December, January and February is 25°F, below both marks. About 125 nights a year here drop to freezing or below, and every one of those nights is below both marks too.
That doesn't mean the house goes cold. It means a standard heat pump is leaning on backup heat, usually electric resistance coils, on most winter nights here, and that backup heat is expensive to run. A furnace burning gas doesn't have that problem. It's built for exactly this job and doesn't lose capacity as it gets colder outside.
If you go with a heat pump here, look at the ENERGY STAR Cold Climate models rather than a standard one. They're tested to hold onto at least 70 percent of their heating capacity at 5°F, which is a different machine than the federal minimum unit the running-cost numbers above are based on. Field tests of cold-climate heat pumps in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. The one night a year here that drops to 0°F or below is a small part of the 125 nights at or below freezing, so a cold-climate heat pump would be doing the real work almost all winter, not just on the mild nights.