Winter here is the real test
Your winter low averages 14°F, and it falls to freezing or below on about 215 nights a year, out of roughly 305 nights in the ten months your heat runs. That is the climate a heat pump has to answer for here, not the mild nights, the cold ones.
A standard heat pump starts falling short of its rated heat output once it's below 40°F outside, and it often needs backup heat once it's below about 35°F. Both marks sit well above your 14°F average low. Every one of those 215 freezing nights falls below both marks. This is not a county where a heat pump runs at full strength through the winter.
Below 0°F, which happens about 19 nights a year here, a standard heat pump is putting out only a fraction of its rated heat. That is a small slice of the winter next to the 215 nights at or below freezing, but it is also the coldest stretch, the nights your house needs the most heat and gets the least of it from the heat pump alone.
A cold climate heat pump is built for exactly this kind of winter. To carry that label it has to prove, under third party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto at least 70 percent of its 47°F capacity at that same temperature. In field testing of prototype cold climate units over two winters in occupied homes, backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup heat alone was rare even above 0°F. If you are set on a heat pump here, this is the version built for your winter, not the standard one.