What winter here does to a heat pump
Heat here runs ten months a year, September through June, and the overnight low averages 25°F across December, January and February. That number matters because a standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to keep up. 25°F is past both marks, and so is every one of the roughly 130 nights a year here that fall to freezing or below.
That doesn't mean the heat pump sits idle. About 130 nights at or below freezing is under half the nights across the ten months you're running heat, so most of the season it's working in conditions it handles fine. And only about one night a year here drops to 0°F or colder, which is the range where a basic heat pump struggles most. Field tests of cold-climate heat pumps in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. So the cold snaps are real, but they're short and few.
The gap between a standard heat pump and a cold-climate one matters here. To earn the ENERGY STAR Cold Climate label, a heat pump has to keep making real heat at 5°F, at least 1.75 units of heat per unit of electricity, and hold onto 70 percent of its 47°F capacity at that temperature. A standard heat pump isn't built to do that. If a heat pump is going into a house here, that rating is what separates one that leans hard on backup heat all winter from one that doesn't.