What cold does to a heat pump here
Winter nights in Lemhi County average 13°F. That's the average low across December, January and February, not the coldest it gets. A standard heat pump's heat output falls short of its rating once it's below 40°F outside, and below about 35°F it often needs backup heat to keep up. Every one of the roughly 195 nights a year that hit freezing or below here is already past both of those marks.
So for more than half the nights in the 11 months the heat runs here, a standard heat pump is working below the point where it makes its full rated heat. On the coldest nights, the ones near 0°F, which happen about 15 times a year, it is leaning on backup heat to make up the difference. A furnace does not have that problem. It burns gas or propane and makes its full heat output regardless of how cold it is outside.
There is a real answer to this, the cold climate heat pump. To carry the ENERGY STAR Cold Climate label, a unit has to keep at least 70 percent of its 47°F heating capacity at 5°F, and still make 1.75 units of heat per unit of electricity at that temperature, verified by outside testing. A two winter field test of these units in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. That is a different machine than the standard heat pump the running cost band above is priced on. If a heat pump is on the table for this house, it needs to be this kind.