Can a heat pump keep up on a 25 degree night
Heat runs eight months a year here, October through May, and the overnight low averages 25°F across December, January and February. About 135 nights a year drop to freezing or below, well over half the nights in that eight month stretch.
A standard heat pump starts losing ground before it gets near that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs a backup heat source to make up the difference. The average winter low here clears both marks, and so does every one of those 135 freezing nights. That is not a rare cold snap. That is most of the winter.
The running cost quoted for a heat pump, $1.54 per 100,000 Btu, assumes that backup heat never runs. Here it will, on the majority of winter nights, and backup heat on a standard heat pump is usually electric resistance heat, the most expensive way to warm a house.
There is an exception worth knowing about. A heat pump built to the ENERGY STAR Cold Climate spec has to prove it still makes at least 1.75 units of heat per unit of electricity at 5°F, and holds onto at least 70 percent of its warm weather heating capacity at that temperature, checked by outside testing. In a two winter field test of prototype cold climate heat pumps, backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. Only about 2 nights a year here reach 0°F. A cold climate heat pump is built for a county like this one. The standard heat pump priced in the running cost band above is not.