What the cold here does to a heat pump
Winter nights in Custer County average 11°F, and about 220 nights a year drop to freezing or below. A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F it already puts out less heat than its rating says. Below about 35°F it typically needs backup heat to keep up. The average night here is below both marks, and every single one of those 220 freezing nights is too.
That doesn't rule out a heat pump. It rules out a standard one. The ones built for this, rated ENERGY STAR Cold Climate, are tested to make at least 1.75 units of heat per unit of electricity at 5°F and hold onto most of their capacity at that temperature. Field tests of cold-climate models in occupied homes found backup heat covering only a small share of the load between 0°F and 35°F, and the units running on backup alone was rare even above 0°F. If a heat pump goes into a house here, it has to be that kind, not the standard one the running-cost comparison above is built on.
About 25 nights a year here reach 0°F or colder, under a quarter of the nights that hit freezing. That's the range where even a good cold-climate heat pump leans hardest on its backup, so whatever heats this house on those nights matters.