An outdoor heat pump unit mounted on a concrete pad in front of a single-story suburban house with beige siding.

Heat Pump Installation in Challis, ID

Tell us about the job

Takes about a minute. No obligation.

New system or replacementHeat PumpCuster County, ID
Step 1 of 2

What ZIP code is the job in?

Electricity heats 59.6% of homes in Custer County, more than any other fuel. That means most of your neighbors are already heating with electric baseboards, electric furnaces, or in some cases a heat pump. A heat pump runs on that same electric service, so going in, there's usually no new gas line or fuel tank to plan around. For a lot of homes here, a heat pump installation is a swap for what's already there, not a switch to a different fuel entirely.

11°F
the average winter night it heats against
73°F
the average summer afternoon it cools against
Isometric cutaway illustration of a single-story house with a dark gabled roof, showing interior rooms with ductwork leading to an indoor air handler and an outdoor condenser unit connected by lines on the ground outside.

Half the homes in Custer County were built in 1986 or earlier.

A standard heat pump sized to the house works whether it's older or newer, no special equipment either way.

A standard heat pump sized for your house handles 11°F nights fine

Power costs 11.52 cents a kWh statewide
140 winter storms from 2015 to 2024
Winter nights average 11°F

Go with the standard fit

A standard size and efficiency fit fine here. There's no local reason to go bigger or pricier.

Find a contractor
A gray heat pump condenser unit mounted on a concrete pad against the gray lap-siding exterior wall of a house.

The right size runs long and steady, not hard and short

A heat pump that's too big cycles on, satisfies the thermostat fast, and shuts off again before it's pulled moisture out of the air or settled into a steady rhythm. That start-stop pattern wears on the compressor more than just running longer would. One that's too small runs on the coldest days and still can't keep up, leaning hard on backup heat strips to make up the difference. Getting the size right means a contractor works out a heat loss and heat gain calculation for the house. Square footage, window area, insulation, ceiling height, orientation, how the house faces the sun all factor in. Houses that look alike from the street can still need different equipment depending on how they're built. Sized right, the compressor runs in long, steady cycles most of the time, which is exactly how it's meant to run.

The outdoor unit and the ductwork are separate jobs

A heat pump is one line item. Getting air from it to every room is another. If the ductwork already in place is sealed well and sized right, a contractor connects to it and moves on. If it's leaky, crushed in places, or was sized for a different kind of system, that gets fixed before the new equipment does any good.

What's already at the electrical panel matters

A heat pump needs its own dedicated circuit, sized for the compressor and any backup heat strips. Some panels have the open space and capacity to take that on without any trouble. Others are already full, or the service coming into the house isn't large enough, and that means panel work before the heat pump goes in at all.

The old equipment doesn't need to come out before the new one goes in. A contractor disconnects the refrigerant lines, recovers whatever refrigerant is left in the system, and removes the indoor and outdoor units once the new heat pump is ready to take over. If the old system was a furnace paired with central air, the furnace and coil come out and the heat pump's air handler or coil takes that spot in the line. If there's an old heat pump already there, it's usually a straight swap at the same pad outside and the same spot on the air handler inside. Refrigerant can't be vented into the air. It gets recovered into tanks and taken off site, which is standard practice on any job that involves a sealed refrigerant system.

Installation day starts outside with the pad and the line set, then moves indoors. A contractor sets the outdoor unit on its pad, runs the refrigerant lines and electrical to it, and connects them to the indoor air handler or coil. Once the lines are connected, the system gets pressure tested to make sure there are no leaks before any refrigerant goes in. Then it's pulled down into a vacuum to clear out air and moisture, since either one left in the lines will cause problems down the road. Refrigerant goes in to the charge the equipment is rated for, and the electrical connections get checked before anything is powered on. Once it's running, a contractor checks airflow at the vents, checks the temperature split between the air going in and the air coming out, and walks through the thermostat before calling the job done.