Winters here run cold, not strange
Pocatello winter nights average 18°F. That's normal heat pump territory. A heat pump built for this climate is sized to handle it, so cold alone doesn't explain a breakdown.

Takes about a minute. No obligation.
Pocatello winter nights average 18°F. That's normal heat pump territory. A heat pump built for this climate is sized to handle it, so cold alone doesn't explain a breakdown.
If your heat pump is struggling, the cause is more likely a failing component, low refrigerant, or a frozen coil than the temperature outside. A contractor can trace it to the actual part and fix that.

NOAA nClimDiv, 1991–2020 normals
A heat pump blowing cold air isn't always broken. It could be stuck in defrost, or it could mean the reversing valve has failed.
If the air stays cold for more than a few minutes and never warms back up, that's the valve, not the cycle.




Electricity here runs 11.52 cents a kilowatt-hour, close to typical for the region. That matters because a heat pump leans on electricity for everything it does, so a system that's running inefficiently costs more to run every month it goes unfixed. It also means repair makes sense here the same way it does anywhere else. There's no local reason to replace instead of repair, and no local reason a repair would cost more than it should. If a contractor traces the problem to a failing part, fixing that part is the job. The electric rate doesn't change what's wrong with the unit, only what it costs you to keep running it broken.
Nothing about this area is especially hard on it. It's most likely the usual problem with the usual fix.
Find a contractorA heat pump runs year round, heating and cooling both, so it never gets the long break a furnace gets between seasons. That changes what fails first. The reversing valve is what switches the system between heating and cooling, and every switch is a part moving that could stick or wear out. The outdoor unit sits exposed through every season, so the coil collects dirt, leaves and whatever else blows into it, and a dirty coil makes the whole system work harder than it should. The compressor logs more running hours than almost anything else in the house, and a compressor that runs constantly is a compressor that eventually wears down. None of that means the unit is failing early. It means the parts carrying the most load are the ones that give out first, and that holds true for any heat pump leaned on through most of the year.
Look at the outdoor unit first. If leaves, ice or snow are packed against the coil, clear them away, that alone can starve airflow enough to cause problems. Check that the outdoor fan is actually spinning when the system calls for heat. Inside, pull the filter and hold it up to light. If you can't see through it, that's enough to choke airflow and ice up the coil. Check the thermostat is set to heat, set above room temperature, and has power. These take a few minutes and rule out the things that aren't a real failure.
Don't knock ice off the coil or chip at it, you can bend the fins or puncture a line that's carrying refrigerant. Don't open the outdoor unit's cabinet looking for a loose wire or a bad part, the components inside hold a charge even with power off. If the breaker trips more than once, stop resetting it, that's the system telling you something is actually wrong, not asking for a restart.
A heat pump that's struggling usually keeps running anyway, since the thermostat just keeps calling for heat. That's when a small problem turns into a bigger one. A coil that's lightly iced will keep icing over as long as airflow stays blocked, until it's solid and the system can't pull any heat off it at all. A compressor working against low refrigerant runs hotter than it's built for, and heat is what wears a compressor down. A reversing valve that's starting to stick gets worked every time the system tries to switch, and a part that sticks once tends to stick again. None of these fix themselves by running longer. Shutting the system off and calling someone doesn't make the repair bigger, it just stops that one part from getting worse while you wait.
A diagnostic visit starts outside, at the unit itself. A contractor checks refrigerant pressure with gauges, since that number tells them right away whether the charge is low and where in the system the problem likely sits. They'll check the temperature split between the air going into the system and the air coming out, because that split says whether the unit is actually moving heat the way it should. The reversing valve gets tested directly, usually by running the system through a cycle and watching whether it actually switches. Electrical parts like the capacitor and contactor get checked with a meter, not by eye, because a capacitor can look fine and still be weak. All of that points to one part, and that's the part that gets fixed.