Gas heats most homes here
Utility gas heats 56% of occupied homes in Bonneville County, and electricity heats most of the rest. A heat pump in this area usually means a change in fuel, not a swap of one box for another.
Takes about a minute. No obligation.
Utility gas heats 56% of occupied homes in Bonneville County, and electricity heats most of the rest. A heat pump in this area usually means a change in fuel, not a swap of one box for another.
Going from a gas furnace to a heat pump means new electrical work alongside the equipment itself, and a decision about whether the furnace stays as backup for the coldest days. Worth asking any contractor how they plan to handle that.

Heat here runs September through June, about ten months straight.
August is the one month to get a heat pump installed before the system has to work.



A standard size and efficiency fit a heat pump here. Idaho homes paid 11.52 cents per kilowatthour in 2024, and that rate doesn't call for anything special in the equipment itself. A correctly sized heat pump will run on what the house actually needs, no more. Going bigger doesn't make it cheaper to run, it just costs more up front and cycles on and off instead of holding steady. Ask the contractor for a load calculation on the house, not a guess based on square footage.
Bonneville County sees its share of wind, hail and winter storms, but none of that changes what the equipment needs to be. A correctly sized heat pump built to standard spec handles it. Get the load calculation done and the installation scheduled.
Find a contractor
Sizing a heat pump means matching its output to how fast the house loses heat in the cold and gains it in the summer, not matching it to the size of the old furnace. An oversized furnace was forgiving. It cycled harder than it needed to, but it got there. An oversized heat pump has a worse problem. It satisfies the thermostat fast, shuts off, and never settles into the slow steady output it's built to run at. That short cycling wears the compressor, and in summer the coil never runs long enough to pull moisture out of the air, so the house can feel damp even at the right temperature. A unit that's too small has its own problem, since it keeps running and still falls behind on the coldest days, leaning on backup heat more than it should. The fix is a load calculation that accounts for insulation, window area and duct layout, not a rule of thumb based on floor space. Ask to see it rather than take the number on faith.
A heat pump needs a line set between the outdoor unit and the indoor coil, plus a circuit sized for the compressor and any backup heat strip. If the furnace it replaces was gas, that circuit often doesn't exist yet. Running it, and routing the line set cleanly through the wall and up to the condenser pad, is labor the old system never needed.
A heat pump installed alongside an existing air handler only works right if the coil inside is rated for that outdoor unit. A mismatched coil undercuts efficiency and can keep the compressor from running the way it's built to. Replacing the coil along with the condenser costs more than reusing one, but reusing the wrong one costs more later.
The efficiency rating on the label tells you how much heat a system moves for the electricity it uses. It doesn't tell you what the house will feel like or what the power bill will show, because that number comes from a lab test under set conditions, not from your ductwork or your walls. A higher rating usually means the compressor can modulate, running at partial output instead of just switching on and off, which is part of why it uses less power to do the same job. That rating is worth comparing between quotes from different contractors, since it's measured the same way across brands. But a unit with a strong rating still needs the right coil match and the right size for the house, or it won't deliver what the label promises. The rating is one piece of the decision, not the whole thing.
The old furnace doesn't have to come out. Plenty of installs keep it in place as backup heat for the days the heat pump can't keep up on its own, wired so the system switches over on its own when it needs to. If it comes out, it's because the space is wanted back or the furnace is old enough that keeping it around doesn't make sense. Either way the gas line gets capped by whoever handles that trade, not left open. A working furnace still has value as a backup, so ask the contractor what they recommend before assuming it has to go.